SOME COMMON ERROR CODE AND THIER
MEANING IN FELICITY INVERTER
Here’s a list of common Felicity inverter error codes and their meanings — these codes may vary slightly depending on your model (e.g., Felicity 1.5kVA, 3.5kVA, 5kVA, 7.5kVA hybrid, etc.), but these are generally accurate across most Felicity solar inverters:
---
⚠️ Felicity Inverter Error Codes and Meanings
Error Code Meaning / Description Possible Cause Recommended Action
E01 Battery Low Voltage Battery voltage dropped below safe level Check battery terminals and voltage; recharge batteries fully.
E02 Battery Over Voltage Input voltage too high Check battery bank connection; ensure correct voltage and polarity.
E03 Output Overload Load exceeds inverter capacity Reduce load; check for short circuit in connected devices.
E04 Output Short Circuit Short circuit on output line Disconnect all loads; inspect wiring and appliances.
E05 Over Temperature Inverter internal temperature too high Ensure ventilation; clean dust; reduce load.
E06 Fan Failure Cooling fan not working Inspect or replace cooling fan.
E07 Input Over Voltage (Solar) PV voltage too high Verify solar panel configuration; reduce number of panels in series.
E08 PV Low Voltage / No PV Input Solar input too low or disconnected Check solar panel connections and voltage level.
E09 Overcharge Protection Battery charging current/voltage too high Check charge controller and battery health.
E10 AC Input Abnormal Grid voltage or frequency out of range Check grid power source; verify wiring.
E11 Communication Failure Communication lost between inverter modules Reconnect communication cables or reset inverter.
E12 EEPROM Error / System Fault Internal program or data error Restart inverter; if persistent, contact service center.
E13 DC Bus Over Voltage DC link voltage too high Check battery and PV configuration.
E14 DC Bus Low Voltage DC link voltage too low Check battery charge status.
E15 Inverter Relay Stuck Output relay malfunction Contact technician or service center.
E16 PV Reverse Polarity PV positive/negative terminals reversed Disconnect panels, correct polarity, and reconnect.
E17 Battery Reverse Polarity Battery connection reversed Disconnect battery and correct polarity immediately.
E18 Current Sensor Fault Internal current detection issue Restart inverter; if persists, service needed.
---
💡 General Troubleshooting Tips
1. Always turn off inverter before checking wiring.
2. Check battery terminals for corrosion or loose connections.
3. Confirm correct PV voltage and polarity before reconnecting.
4. Ensure inverter is in a well-ventilated area to avoid overheating.
5. If multiple errors persist, reset the inverter or contact a Felicity service center