Electronique & Electricité

Electronique & Electricité U = R x I 🙂
(3)

This illustration shows the T568A and T568B wiring standards used for Ethernet cables (RJ45 connectors). Both standards ...
04/11/2025

This illustration shows the T568A and T568B wiring standards used for Ethernet cables (RJ45 connectors). Both standards define the pinout order of the eight wires inside a twisted-pair cable, ensuring proper network connectivity. The main difference lies in the arrangement of the green and orange pairs: T568A places the green pair on pins 1 and 2, while T568B places the orange pair there. Functionally, both work the same for straight-through cables if both ends use the same standard, but T568B is more commonly used in the U.S. for network installations.

If You Recognize This Screen, You’re Lucky Enough to Have Lived Through the Golden Age of Technology’s Evolution
19/09/2025

If You Recognize This Screen, You’re Lucky Enough to Have Lived Through the Golden Age of Technology’s Evolution

Most engineers confuse these two concepts!PROTECTIVE EARTHING (PE) vs FUNCTIONAL EARTHING (FE).During my years in contro...
20/08/2025

Most engineers confuse these two concepts!
PROTECTIVE EARTHING (PE) vs FUNCTIONAL EARTHING (FE).

During my years in control panel design, I still see this common mistake in drawings!

🎯 The difference between them:

âś… Protective Earthing (PE):
• Green/Yellow wire 🟡🟢
• Carries fault current ⚡
• Triggers breakers to protect the system
• Main purpose: Save lives! ♥️

âś… Functional Earthing (FE):
• Usually a braided strap 🔗
• Removes high-frequency noise 📢
• Improves EMC stability (Electromagnetic Compatibility)
• Main purpose: Protect electronics! 📱💻

📌 Quick takeaway:
PE = Safety First!
FE = Performance Matters!

19/08/2025
Power Factor Capacitors improve efficiency in electrical systems by supplying reactive power to counteract inductive loa...
18/08/2025

Power Factor Capacitors improve efficiency in electrical systems by supplying reactive power to counteract inductive loads (motors, transformers).

Benefits: lower electricity costs, better system performance, avoid utility penalties, and increase network capacity.

Types:
1- fixed (for steady loads)
2- automatic (for variable loads).