KGM Engineering Services

KGM Engineering Services Offering Plumbing and Electrical Engineering Solutions to meet your needs.

Services Offered:
-Plumbing Design, Cost estimate and Technical Specifications
-Review and Sign and Seal of Plumbing Plans
-Sign and seal of Sewerage Connectivity Plan
-Sign and seal of as-built plumbing plans
-Plumbing Works In-Charge
-Certificate of Completion
-Other documents related to plumbing.

Design Review and Sign and seal of Plumbing Plan for a Gasoline Station at Masinloc, ZambalesOur heartfelt thanks to our...
11/09/2026

Design Review and Sign and seal of Plumbing Plan for a Gasoline Station at Masinloc, Zambales

Our heartfelt thanks to our valued client for trusting and availing our services.

For electrical and plumbing engineering solutions, we’re only a message away!
🌟 Our Services:
βœ… Electrical System Design
βœ… Electrical Design Analysis / Power System Studies
βœ… Plumbing System Design and Analysis
βœ… Sign and Seal of Building Plans
βœ… Permits Application and Assistance
βœ… Consultations

πŸ“ž Contact Us!
πŸ“§ [email protected]
πŸ“² 0949-7039-889

23/08/2026

Conducting Insulation Resitance Test of 15kV Bus Insulator prior to energization. Weather condition: Rainy πŸ“ˆβš‘πŸ‘·

Warehouse Fit-out Electrical Design for a Manufacturing Facility at Subic Bay Gateway Park.Our heartfelt thanks to our v...
09/08/2026

Warehouse Fit-out Electrical Design for a Manufacturing Facility at Subic Bay Gateway Park.

Our heartfelt thanks to our valued client for trusting and availing our services.

For electrical and plumbing engineering solutions, we’re only a message away!
🌟 Our Services:
βœ… Electrical System Design
βœ… Electrical Design Analysis / Power System Studies
βœ… Plumbing System Design and Analysis
βœ… Sign and Seal of Building Plans
βœ… Permits Application and Assistance
βœ… Consultations

πŸ“ž Contact Us!
πŸ“§ [email protected]
πŸ“² 0949-7039-889

Thermal Scanning of newly renovated DinerFindings: Thermal anomaly on 3TR floor mounted Aircon branch circuit and Wire p...
02/07/2026

Thermal Scanning of newly renovated Diner

Findings: Thermal anomaly on 3TR floor mounted Aircon branch circuit and Wire prone to physical damage

Cause:
-Undersized branch circuit (3.5mm2) and

Recommended Corrective Action:
-Replace existing wire with correct size based on equipment load.
-Use appropriate conduit fittings connecting to panel

Ensure safety on your electrical system by detecting unseen hazards. πŸ“‹βœ…

For your thermal scanning requirements, DM this page. ⚑🎯

Repair of 38mm2 15kV Power Cable due to rodents (Rat Bites). πŸ­πŸ§€βš‘Problem: Found Open 1 Power Fuse causing single phasing....
23/06/2026

Repair of 38mm2 15kV Power Cable due to rodents (Rat Bites). πŸ­πŸ§€βš‘

Problem: Found Open 1 Power Fuse causing single phasing.

Findings: Damaged power cable exposing grounding shield due to rat bite

Corrective action:
-Apply high voltage self bonding insulation tape and water proof tape.
-Replace busted power fuse
-Conducted Insulation Resistance Test on the repaired cable to ensure insulation integrity prior to energization.

Attending the 27th IIEE Central Luzon Regional Convention last June 18-20, 2026 at Royce Hotel, Clark, Pampanga. Gaining...
21/06/2026

Attending the 27th IIEE Central Luzon Regional Convention last June 18-20, 2026 at Royce Hotel, Clark, Pampanga.

Gaining latest trends and technology in the electrical engineeeing industry. πŸ‘·πŸŽ―βš‘

Happy Father's day!
21/06/2026

Happy Father's day!

Completed Electrical As built Plan and Power System Analysis (voltage drop and short circuit analysis) of 1.6MVA 13.8/0....
11/06/2026

Completed Electrical As built Plan and Power System Analysis (voltage drop and short circuit analysis) of 1.6MVA 13.8/0.4-0.23kV Manufacturing plant at Subic. πŸ‘·βš‘

Data gathering in preparation for electrical system as built and power system analysis of 1.6MVA 13.8/0.4-.23kV manufact...
23/05/2026

Data gathering in preparation for electrical system as built and power system analysis of 1.6MVA 13.8/0.4-.23kV manufacturing plant in Subic. βš‘πŸŽ―πŸ‘·

Another day, another Thermal Scanning 🌑⚑Checking a household electrical panel somewhere in Kalayaan, Subic Bay Freeport ...
15/05/2026

Another day, another Thermal Scanning 🌑⚑

Checking a household electrical panel somewhere in Kalayaan, Subic Bay Freeport Zone to check for thermal anomalies.

Wise decision by the Client to ensure safety and reliability at his home.

For thermal scanning services, PM is the key πŸ”‘!