Tee & Zara II

Tee & Zara II Follow for more 💜🙏

I think my FIL is trying to set my house on fire! LolSo we live in California. We bought a home and I guess code require...
12/06/2025

I think my FIL is trying to set my house on fire! Lol
So we live in California. We bought a home and I guess code requires the type of breakers for the kitchen in slot 11 and 13 . I dont know anything about electricity other than if a breaker falls, first identify why then push it all the way to the left then to the right to reset. We'll these new ones have a built in reset button. We were told that the whole house was rewired when we bought it. Fast forward 2 years.

I started hearing a humming when id pass the breaker box and sure enough later in the evening the fridge was off. The outlets to the breaker only had the fridge and an air fryer on the breaker that tripped. I went to press the reset button but it wouldn't reset so id push the left then right to turn it back on. Once id do that id hear a sizzle sound and see some sparks in the back. I left it off and told my wife. She told me her father used to be an electrician, probably around the time electricity was invented because he's old AF. He was also Jesus' father's carpenter apprentice. Yes he's ooooold. Well he came by took a look. Said let's replace the breaker. These aren't cheap, they're like 70-80 bucks each. We'll everything was fine for 2 weeks and then our microwave went out and my wife had the smart idea to buy a bigger one that didn't fit into the microwave designated area so we were using it on top of the island which also shares the same breaker as the fridge while she sold it on fb marketplace. Guess what, it started happening again.

My wife called my FiL again and he started complaining about how these breakers are so delicate that back in his day they would just use the ones on the right give the inspector a beer and call it a day. He suggested we use that same type of breaker on the left for the fridge but I know that since there is no gfci outlet behind the fridge, code requires these types. Am I being overly cautious? Is my FiL right or is he just old timey? I dont want to keep replacing the breaker at 70 bucks a pop (no pun intended) and feel that the fridge and other appliances should be able to be on that breaker with no issues but i could be wrong. im also hating having to empty the fridge into coolers, go buy ice and have to live like im camping in my home while this gets resolved. We've removed everything from the outlets that feed that breaker except the fridge and plan to keep it that way moving forward. FiL coming tomorrow to replace the breaker again. Kinda at a loss as to whats happening. Any advice appreciated.

Service electrician didn't know how to test a motor.I'm a maintenance electrician at a chemical plant and we have a on-s...
12/06/2025

Service electrician didn't know how to test a motor.
I'm a maintenance electrician at a chemical plant and we have a on-site nitrogen generating installation from Air Liquide (AL). It's their equipment, we aren't allowed to touch it, we just supply power and use the nitrogen gas.

Last night an alarm sounded and the nitrogen installation failed to power up. So this morning I see the door from the frequency drive panel blown open and half ripped off, covered in soot. 500A fuses blown, big bang, they were pretty welded in there.

AL send 2 service electricians to replace the frequency drive, I asked them if they needed help but they said: no bro we do this all the time. So these guys replaced the 250kW drive and then one comes to my desk asking if I could megger the motor for them, because they forgot their own. I'm like: who the hell forgets a megger when going to such a job. I was kinda busy so I said: please prepare the motor, call me when you're ready.

They called and when I came over they had just disconnected the motor cable from the drive, cable was still connected to the motor. So I'm like: what the hell, I can't test that motor like this. Both of them gave me the thousand yard stare and said they didn't get it. So I told them they had to disconnect the motor cable from the motor and remove the internal links from the terminals. The guy asked me why, so I explained to him that in order to measure between the separate windings you have to remove the links. Also to measure the winding resistance. He said he never done that and just meggered between phase and earth from the cable.

Motor was OK, but I was astonished that these guys didn't know how to test a motor. This is basic knowledge right, or am I overreacting?

Home insurance asking us to better secure wires from service mast. Are they wrong?Our home insurance company had an insp...
12/06/2025

Home insurance asking us to better secure wires from service mast. Are they wrong?
Our home insurance company had an inspector come out and tell us that the loose wires on the side of our house was a safety hazard. They asked that we better secure them to the mast of our house so that they don’t move around when it’s windy out. Is this something that they’re correct on or is our service mast wires just fine? Wondering if we need to call our utility company or not to have this looked at and fixed. They’re saying it a big safety hazard atm.

Can I Cut this Safely?I have an electrical panel that I want to salvage as you can see in the second photo. I noticed th...
12/06/2025

Can I Cut this Safely?
I have an electrical panel that I want to salvage as you can see in the second photo. I noticed there was no voltage to the box/line at all. I see that the fuse has been detached on the telephone pole (red arrow). As far as my understand goes for this type of electrical pole (hot on top neutral on bottom) everything past the transformer should be completely dead. Am I able to cut the wire in the green circle and salvage everything past that point? I don’t want to mess with the transformer or get any closer than I need.

TLDR; can I cut the wire in the green circle?

Help! This is my main electric service line coming into my house. How do I fix this?
12/06/2025

Help! This is my main electric service line coming into my house. How do I fix this?

Electrician told us we shouldn’t remove this wire!Hi everyone. Electrician said this cable wire that feeds into our upst...
12/06/2025

Electrician told us we shouldn’t remove this wire!
Hi everyone. Electrician said this cable wire that feeds into our upstairs bedroom shouldn’t be removed. That it’s connected through the house and will make more problems?… we have no need for it? Should I rip it up or what

Circuit Breaker TypeI have to replace a circuit breaker in my old home. I know these are probably outdated but what kind...
12/06/2025

Circuit Breaker Type
I have to replace a circuit breaker in my old home. I know these are probably outdated but what kind of circuit breaker are these?

Decided to have a look at the sub panel in my house. I’m not an electrician, but this looks like disaster. Calling a pro...
12/06/2025

Decided to have a look at the sub panel in my house. I’m not an electrician, but this looks like disaster. Calling a pro first thing in the morning.

You boys ever play with 700 volt 400 hz stuff?
12/06/2025

You boys ever play with 700 volt 400 hz stuff?

What kind of breakers would go on this?I know my way around basic electrical work, however I can't seem to find which ki...
12/06/2025

What kind of breakers would go on this?
I know my way around basic electrical work, however I can't seem to find which kinds of breakers would go on this. What would this kind of connector design be called? This is a older building I'm dealing with.

Could this ground conductor at my service mast be a reason for water getting in my main panel?The service masts drop dow...
12/06/2025

Could this ground conductor at my service mast be a reason for water getting in my main panel?
The service masts drop down into the meter, and the meter runs through my foundation wall into my panel. I’ve found the water is traveling through my jacketed main service into my panel. It only happens when there is severe rainfall. I have a feeling since it’s the conductor going into my mast, I own that portion and can’t pin it on the utility company. I bought this house 6 months ago.

I am trying to buy a home and this was flagged on my inspection. Am I able to fix this myself ?
12/06/2025

I am trying to buy a home and this was flagged on my inspection. Am I able to fix this myself ?

Address